Estou com um problema de superaquecimento no meu Dell Inspiron 15R e instalado i8kmon
para controlar a velocidade do ventilador no Ubuntu 14.04 .
Aqui está uma cópia da saída 'lm-sensores':
coretemp-isa-0000
Adapter: ISA adapter
Physical id 0: +62.0°C (high = +87.0°C, crit = +105.0°C)
Core 0: +57.0°C (high = +87.0°C, crit = +105.0°C)
Core 1: +61.0°C (high = +87.0°C, crit = +105.0°C)
i8k-virtual-0
Adapter: Virtual device
Right Fan: 0 RPM
CPU: +62.0°C
Mesmo ao definir os limites de temperatura /etc/i8kmon
para:
set config(daemon) 1
# Automatic fan control, override with --auto option
set config(auto) 1
# Report status on stdout, override with --verbose option
set config(verbose) 1
# Status check timeout (seconds), override with --timeout option
set config(timeout) 1
# Temperature thresholds: {fan_speeds low_ac high_ac low_batt high_batt}
set config(0) {{0 -} -1 55 -1 55}
set config(1) {{1 -} 55 70 55 70}
set config(2) {{2 -} 60 128 60 128}
O ventilador não inicia quando deveria. Alguma idéia do que pode estar errado? Aqui está uma cópia do log
ao executar i8kmon
manualmente com a --verbose
opção:
i8kmon v1.30 11/16/2013 - Copyright (C) 2013 Vitor Augusto <[email protected]>
config(0) = {0 0} -1 60 -1 65
config(1) = {1 0} 50 70 55 75
config(2) = {1 1} 60 80 65 85
config(3) = {2 2} 70 128 75 128
config(acpi) = acpi
config(auto) = 1
config(daemon) = 1
config(geometry) =
config(i8kfan) = /usr/bin/i8kfan
config(min_speed) = 2000
config(sysconfig) = /etc/i8kmon.conf
config(t_high) = 80
config(timeout) = 5
config(unit) = C
config(use_conf) = 1
config(userconfig) = ~/.i8kmon
config(verbose) = 1
status(ac) = 0
status(acpi_timer) = 0
status(left) =
status(leftspeed) = 0 -1 -1 -1
status(lspeed) = 0
status(lstate) = 0
status(lstuck) = 0
status(nfans) = 2
status(right) =
status(rightspeed) = 0 0 0 0
status(rspeed) = 0
status(rstate) = 2
status(rstuck) = 0
status(state) = 0
status(t_high) = 0
status(t_low) = 0
status(temp) = 0
status(timer) =
status(ui) = 0
1410467738 acpi: Battery 0: Discharging, 89%, 03:13:17 remaining
temp, left, right, ac state: 60 -1 2 0
# exec /usr/bin/i8kfan 0 0
temp, left, right, ac state: 59 -1 0 0
# exec /usr/bin/i8kfan 0 {}
temp, left, right, ac state: 58 -1 0 0
# exec /usr/bin/i8kfan 0 {}
temp, left, right, ac state: 58 -1 0 0
# exec /usr/bin/i8kfan 0 {}
temp, left, right, ac state: 60 -1 0 0
# exec /usr/bin/i8kfan 0 {}
temp, left, right, ac state: 58 -1 0 0
# exec /usr/bin/i8kfan 0 {}
temp, left, right, ac state: 59 -1 0 0
# exec /usr/bin/i8kfan 0 {}
temp, left, right, ac state: 58 -1 0 0
# exec /usr/bin/i8kfan 0 {}
temp, left, right, ac state: 58 -1 0 0
# exec /usr/bin/i8kfan 0 {}
temp, left, right, ac state: 60 -1 0 0
Parece que as temperaturas estão erradas e i8kmon
não estão ligando o ventilador.
fonte
lm-sensors
quando seu ventilador está funcionando e verifica o resultadoRight Fan: 0 RPM
se você vê alguma alteração? e uma pergunta extra, você gosta de rodar quando a CPU é maior?Right Fan: 78000 RPM
mas a temperatura parece bastante alta.CPU: +69.0°C
. Na verdade, ele começa a funcionar quando a atividade da CPU é maior.i8kmon
parai8kmon.conf
e definirset config(daemon) 1
aset config(daemon) 0
eset config(timeout) 1
aset config(timeout) 20
e também substituir-
com-1
valor em cada estadoex{- 1}
para{-1 1}
ans assim por diante. e finalmente rodari8kmon
no terminal você verá se funciona ou não. você pode ver askubuntu.com/a/308548/283843 ou ubuntuforums.org/archive/index.php/t-842775.html para obter mais detalhes